Cutting-Edge Application | Research on Rock Grouting Seepage Mechanism Based on Low-Field NMR Technology

Published on: 2026-11-25 16:38

With the growing demand for the development and utilization of underground spaces, numerous deep-buried tunnels are being constructed successively. During tunnel construction, unfavorable geological bodies such as faults and karst fracture zones are frequently encountered. These rock masses have low strength and are prone to forming water-conducting channels under strong disturbance and high water pressure, making groundwater inrush in fractured rock masses a prominent disaster type in deep tunnels, potentially causing significant property loss and casualties.

Grouting is an effective means to mitigate the adverse effects of groundwater on underground structures, reduce the permeability of fractured rock, and prevent water from seeping into structures. It has been widely used in underground engineering for water inrush control and surrounding rock reinforcement. Among these, cement-based grouting materials have become the most commonly used due to their high strength, good durability, and low cost. Bentonite, owing to its good rheological properties, controllable bleeding, and ability to form low-permeability hardened bodies, is often mixed in to prepare clay-cement grouting mixtures, especially suitable for the sealing and reinforcement of deep fractured rock masses.

Traditional seepage tests (evaluating sealing effects by comparing permeability coefficients before and after grouting) have obvious limitations: they can only provide macroscopic static parameters of the initial and final stages, failing to visualize the real-time migration behavior of fluids within the grouting-modified fractured rock during the seepage process. Due to the complex internal structure of the rock mass, the microscopic structural evolution and fluid distribution during the actual seepage process are difficult to observe, fundamentally hindering the mechanistic understanding of “how grouting achieves seepage reduction.”

Advanced monitoring technologies such as Low-Field NMR (LF-NMR) and Magnetic Resonance Imaging (MRI) offer the possibility to break through these limitations. Not only can LF-NMR be used for quantitative analysis of pore structure evolution and permeability, but MRI can also be used to visualize the grouting process. By organically integrating the two, it is possible to simultaneously visualize microscopic structural evolution and fluid migration behavior within the same seepage process. Therefore, systematically elucidating the seepage reduction effect of the self-developed cement-based grouting material containing a large amount of bentonite on fractured rock is of great significance for optimizing grouting material performance and supporting the prevention and control of water inrush in underground engineering.

Research Case

Investigation on seepage reduction characteristics of cement-based grout on fractured rock using LF NMR and imaging techniques[1]:

  1. Sample Information

Rock sample: Sandstone, uniaxial compressive strength 30.95 MPa, elastic modulus 1.63 GPa, Poisson’s ratio 0.32.

Pre-cut fracture: A single fracture with an axial cutting length of 15 mm and an aperture of 1.5 mm.

Self-developed slurry components: Cement, sodium bentonite, mass ratio; water-solid ratio.

Grouting: Admixture 10%, water 1%, water 1%… (Note: Original text formatting error for the mix ratio), DN superplasticizer 1%; water glass 2%.

Grouting process: Wrap rock sample with tape → reserve grouting hole → slowly inject into pre-cut fracture with a syringe → stir and exhaust air with fine iron wire → standard curing for 28 d with the hole facing up → remove tape and polish → ultrasonic wave velocity re-test and screening (discard abnormalities).

Figure 1: Sample Processing

  1. Experimental Equipment:

Low-Field NMR: MacroMR12-110H-I (Suzhou Niumag Analytical Instrument Corporation)

Figure 2: Testing Equipment

III. Seepage Experiment Plan:

  1. Sample drying:

To eliminate the influence of initial moisture content differences on the results, all samples were first dried at 60°C for 24 hours, then wrapped in plastic film and stored in a desiccator until testing.

  1. System assembly:

Place the sample into the core holder, then place the holder into the magnet, and connect the confining pressure and hydraulic control systems.

  1. Apply confining pressure:

Pump fluorinert oil into the confining pressure line via a circulation pump until the predetermined confining pressure value is reached.

  1. Start seepage:

Start the hydraulic control system to apply seepage water pressure and begin the seepage test. During the seepage process, the CPMG sequence is used to continuously measure the T2 signal.

  1. MRI imaging:

MRI imaging and signal acquisition are performed at the following five state nodes: initial T2 signal appearance (Initial signal), continuous T2 signal change during seepage (Continuous change I and Continuous change II), water begins to emerge at the sample end (Breakthrough outflow), and T2 signal stabilization (Signal stabilization).

  1. Quantitative characterization of permeability:

After water continuously flows out and the T2 signal stabilizes, measure the volume of water discharged from the sample end within 10 min using a graduated cylinder, then terminate the test and shut down the system.

  1. Experimental Analysis

1D Relaxation T2 Spectrum Detection Results:

Figure 3: NaCl-containing grouting modified seepage T2

The figure divides pore types into three regions by color: Micropore, Mesopore, and Macropore. Each subplot contains signal curves of five seepage stages: Initial signal, Continuous change I, Continuous change II, Breakthrough outflow, and Signal stabilization.

Figure 3 shows that during the seepage process of NaCl-containing grout modified fractured rock, as seepage progresses, the T2 spectrum gradually evolves from an initial bimodal (or unimodal) distribution to a unimodal distribution, with the peak value and peak width continuously increasing and shifting to the right. The fluid first enters the micropores and mesopores, then gradually expands to the macropores, and finally almost fills the entire pore space. The sample reaches full saturation at the signal stabilization state. This evolution is mainly attributed to the active pore expansion activities inside the sample under water-rock interaction, leading to pore development and an increase in pore size.

Figure 4: CaCl2-containing grouting modified seepage T2

Comprehensive analysis of the seepage processes of NaCl-containing grout and CaCl2-containing grout modified fractured rock reveals a consistent seepage pattern: the initial stage is dominated by fluid expansion in micropores and mesopores, then gradually expands to macropores, and finally establishes hydraulic equilibrium after forming the main seepage channel, completing the entire seepage process. Figure 4, as the T2 spectrum of the CaCl2-containing grout system, intuitively demonstrates this evolution process.

Imaging Detection Results:

Figure 5: MRI images of grouting modified seepage process

Figure 5 contains two subplots: (a) and (b), corresponding to grouting modified samples with NaCl content of 2.5% and CaCl2 content of 0.1%, respectively.

Each subplot contains an MRI image sequence of five seepage stages: Initial signal, Continuous change I, Continuous change II, Breakthrough outflow, and Signal stabilization.

MRI technology intuitively displays the spatial distribution and dynamic evolution of fluids inside the grouting modified fractured rock during the seepage process: the signal intensity continuously increases as seepage advances, indicating that the fluid gradually infiltrates and fills the pore spaces inside the sample; at the breakthrough outflow stage, water begins to emerge at the sample end, after which the signal tends to stabilize, indicating that a stable seepage channel has formed inside the sample and hydraulic equilibrium has been established. The signal evolution trends of the two samples are generally consistent, but there are differences in signal distribution morphology, reflecting the influence of different chloride salt types and contents on the pore structure of the hardened grout, which in turn affects the fluid seepage paths and distribution characteristics in the modified fractured rock.

Low-Field NMR technology achieves quantitative characterization of pore structure features, including porosity, fluid saturation, and pore size distribution, by analyzing the relaxation behavior of hydrogen nuclei in fluids. The evolution of the T2 spectrum reveals the fluid diffusion laws during the seepage process—from initial distribution in micropores and mesopores to gradual expansion into macropores until fully saturated; the T2 spectrum area quantitatively reflects the dynamic changes in fluid content inside the sample, revealing pore development and expansion under water-rock interaction; meanwhile, the permeability contribution calculated based on the NMR T2 spectrum quantitatively evaluates the relative contribution of different pore types to the seepage process.

MRI technology converts the spatial distribution of fluids inside the rock mass during the seepage process into pseudo-color images, where the signal intensity reflects the size and quantity of pores or fractures. By comparing the MRI images of samples under different grout types and proportions, the anti-seepage performance of different grouting materials can be intuitively evaluated.

Recommended Equipment

Large-Bore NMR Imaging Analyzer

 

Reference:

[1] Niu X, Feng G, Han Y, et al. Investigation on seepage reduction characteristics of cement-based grout on fractured rock using LF NMR and imaging techniques[J]. Construction and Building Materials, 2026, 520:145991-145991.